Suppression of temperature influence in mass-sensitive chemical sensors by signal processing

Title data

Adam, Michael ; Fischerauer, Gerhard:
Suppression of temperature influence in mass-sensitive chemical sensors by signal processing.
In: Eurosensors XXII : Proceedings. - Düsseldorf : GMA , 2008 . - pp. 977-980
ISBN 978-3-00-025217-4

Abstract in another language

Mass-sensitive chemical sensors such as surface acoustic wave (SAW) resonators suffer from their cross-sensitivity to temperature. We report on an approach to remedy this problem which is based on the fact that device characteristics such as the resonance frequency (f₀) and the transfer function magnitude (|S₂₁|) respond differently to the measurand and the interfering temperature.