Eckel, Hans-Günter ; Gierschner, Sidney ; Bakran, Mark-M.:
A competitive medium frequency AC distribution grid for offshore wind farms using HVDC.
In:
15th European Conference on Power Electronics and Applications (EPE) 2013 : Proceedings. -
Lille, Frankreich
,
2013
DOI: https://doi.org/10.1109/EPE.2013.6634385
Abstract
HVDC transmission becomes more important for wind farms located over hundred kilometres from the shore. For offshore wind farms decoupled by HVDC transmission, frequency is a degree of freedom. State of the art for offshore wind farms is a 50Hz AC distribution grid. In this paper the effects of a higher line frequency on the main parts of an offshore wind farm are investigated. The main advantages and drawbacks are revealed and compared to a wind farm topology using a DC distribution grid. A loss calculation for a whole wind farm was done to highlight the opportunities and restrictions.
Weitere Angaben
Publikationsform: | Aufsatz in einem Buch |
---|---|
Begutachteter Beitrag: | Ja |
Institutionen der Universität: | Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Mechatronik > Lehrstuhl Mechatronik - Univ.-Prof. Dr.-Ing. Mark-M. Bakran Fakultäten Fakultäten > Fakultät für Ingenieurwissenschaften Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Mechatronik Profilfelder > Emerging Fields > Energieforschung und Energietechnologie Profilfelder Profilfelder > Emerging Fields |