Titelangaben
Gleißner, Michael ; Bakran, Mark-M.:
Operation of fault-tolerant inverters with DC-link midpoint connection for adjustable speed drives.
2018
Veranstaltung: EPE 2018 : 20th European Conference on Power Electronics and Applications
, 17.09.-21.09.2018
, Riga, Lettland.
(Veranstaltungsbeitrag: Kongress/Konferenz/Symposium/Tagung
,
Paper
)
Abstract
Some fault-tolerant three-phase inverters are based upon a reconfiguration to an inverter with only two
active phases and a DC-link midpoint connection after any semiconductor failure. Thus, the maximum
output voltage is halved and the DC-link midpoint capacitor voltage ripple depends on output frequency
and output current of the inverter. These limiting effects on the operation range of adjustable speed drives
as well as software and hardware based countermeasures are presented in this paper.
Weitere Angaben
Publikationsform: | Veranstaltungsbeitrag (Paper) |
---|---|
Begutachteter Beitrag: | Ja |
Institutionen der Universität: | Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Mechatronik > Lehrstuhl Mechatronik - Univ.-Prof. Dr.-Ing. Mark-M. Bakran Fakultäten Fakultäten > Fakultät für Ingenieurwissenschaften Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Mechatronik |
Titel an der UBT entstanden: | Ja |
Themengebiete aus DDC: | 600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften |
Eingestellt am: | 13 Nov 2018 08:31 |
Letzte Änderung: | 19 Nov 2018 08:30 |
URI: | https://eref.uni-bayreuth.de/id/eprint/46297 |