Title data
Gleißner, Michael ; Bakran, Mark-M.:
Operation of fault-tolerant inverters with DC-link midpoint connection for adjustable speed drives.
2018
Event: EPE 2018 : 20th European Conference on Power Electronics and Applications
, 17.09.-21.09.2018
, Riga, Lettland.
(Conference item: Conference
,
Paper
)
Abstract in another language
Some fault-tolerant three-phase inverters are based upon a reconfiguration to an inverter with only two
active phases and a DC-link midpoint connection after any semiconductor failure. Thus, the maximum
output voltage is halved and the DC-link midpoint capacitor voltage ripple depends on output frequency
and output current of the inverter. These limiting effects on the operation range of adjustable speed drives
as well as software and hardware based countermeasures are presented in this paper.
Further data
Item Type: | Conference item (Paper) |
---|---|
Refereed: | Yes |
Institutions of the University: | Faculties > Faculty of Engineering Science > Chair Mechatronics > Chair Mechatronics - Univ.-Prof. Dr.-Ing. Mark-M. Bakran Faculties Faculties > Faculty of Engineering Science Faculties > Faculty of Engineering Science > Chair Mechatronics |
Result of work at the UBT: | Yes |
DDC Subjects: | 600 Technology, medicine, applied sciences > 620 Engineering |
Date Deposited: | 13 Nov 2018 08:31 |
Last Modified: | 19 Nov 2018 08:30 |
URI: | https://eref.uni-bayreuth.de/id/eprint/46297 |