Literatur vom gleichen Autor/der gleichen Autor*in
plus bei Google Scholar

Bibliografische Daten exportieren
 

The 450 nm (2.8 eV) cathodoluminescence emission in quartz and its relation to structural defects and Ti contents

Titelangaben

Götze, Jens ; MacRae, Colin M. ; Pan, Yuanming ; Wilson, Nicholas C. ; Torpy, Aaron ; Audétat, Andreas:
The 450 nm (2.8 eV) cathodoluminescence emission in quartz and its relation to structural defects and Ti contents.
In: American Mineralogist. Bd. 109 (2024) Heft 1 . - S. 122-134.
ISSN 1945-3027
DOI: https://doi.org/10.2138/am-2022-8884

Volltext

Link zum Volltext (externe URL): Volltext

Abstract

The origin of the common blue 450 nm (2.8 eV) cathodoluminescence (CL) emission in natural and synthetic quartz has been investigated using a combination of CL microscopy and spectroscopy, electron paramagnetic resonance (EPR) spectroscopy, and trace-element analysis by electron micro-probe analysis as well as inductively coupled plasma-mass spectrometry (ICP-MS). The study shows that the appearance of the ~450 nm emission band can be attributed to two different defects in quartz. First, a transient luminescence can be explained by structural defects in oxygen deficient quartz. The luminescence model implies self-trapped exciton (STE) emission related to oxygen vacancies. This type of CL emission is frequent in high-purity synthetic quartz and natural quartz of hydrothermal origin. Second, in Ti-rich quartz from natural samples (e.g., quartz phenocrysts in rhyolites) and synthetic quartz of Ti-diffusion experiments, an additional 450 nm (2.8 eV) emission was detected, which is stable under the electron beam. The intensity of this ~450 nm emission band correlates with the concentration of trace Ti in quartz, and substitutional Ti4+ at the Si4+ position was proved by EPR spectroscopy. In quartz crystals with elevated Ti concentrations both intrinsic and extrinsic blue CL emissions at ~450 nm can coexist, hindering a thorough characterization and quantification of the CL signal. A reliable distinction of the two different CL emission bands is possible by fitting the peaks of the CL spectra, and the peak width of the 450 nm emission can be used to differentiate the STE from the Ti4+ emission. However, the definitive technique is through the observation of CL peak shape change over time at a point by collecting a time series of CL spectra in conjunction with EPR spectroscopy and trace-element analysis of the Ti concentration.

Weitere Angaben

Publikationsform: Artikel in einer Zeitschrift
Begutachteter Beitrag: Ja
Institutionen der Universität: Fakultäten > Fakultät für Mathematik, Physik und Informatik > Fachgruppe Materialwissenschaften > Lehrstuhl Kristallographie
Titel an der UBT entstanden: Ja
Themengebiete aus DDC: 500 Naturwissenschaften und Mathematik > 530 Physik
Eingestellt am: 22 Okt 2024 08:32
Letzte Änderung: 22 Okt 2024 08:32
URI: https://eref.uni-bayreuth.de/id/eprint/90791