Literatur vom gleichen Autor/der gleichen Autor*in
plus bei Google Scholar

Bibliografische Daten exportieren
 

The dynamic chamber method: trace gas exchange fluxes (NO, NO2, O3) between plants and the atmosphere in the laboratory and in the field

Titelangaben

Breuninger, Claudia ; Oswald, R. ; Kesselmeier, Jürgen ; Meixner, Franz X.:
The dynamic chamber method: trace gas exchange fluxes (NO, NO2, O3) between plants and the atmosphere in the laboratory and in the field.
In: Atmospheric Measurement Techniques Discussions. Bd. 4 (2011) . - S. 5183-5274.
ISSN 1867-8610
DOI: https://doi.org/10.5194/amtd-4-5183-2011

Abstract

We describe a dynamic chamber system to determine reactive trace gas exchange fluxes between plants and the atmosphere under laboratory and, with small modifications, also under field conditions. The system allows measurements of the flux density of the reactive NO-NO2-O3 triad and additionally of the non-reactive trace gases CO2 and H2O. The chambers are made of transparent and chemically inert wall material and do not disturb plant physiology. For NO2 detection we used a highly NO2 specific blue light converter coupled to chemiluminescence detection on the photolysis product, NO. Exchange flux densities derived from dynamic chamber measurements are based on very small concentration differences of NO2 (NO, O3) between inlet and outlet of the chamber. High accuracy and precision measurements are therefore required, and high instrument sensitivity (limit of detection) and the statistical significance of concentration differences are important for the determination of corresponding exchange flux densities, compensation point concentrations, and deposition velocities. The determination of NO2 concentrations at sub-ppb levels (2 analyzer with a lower detection limit (3σ-definition) of 0.3 ppb or better. Deposition velocities and compensation point concentrations were determined by bi-variate weighted linear least-squares fitting regression analysis of the trace gas concentrations, measured at the inlet and outlet of the chamber. Performances of the dynamic chamber system and data analysis are demonstrated by studies of Picea abies L. (Norway Spruce) under field and laboratory conditions. Our laboratory data clearly show that highly significant compensation point concentrations can only be detected if the NO2 concentration differences were statistically significant and the data were rigorously controlled for this criterion. The results of field experiments demon strate the need to consider photo-chemical reactions of NO, NO2, and O3 inside the chamber for the correct determination of the exchange flux densities, deposition velocities, as well as compensation point concentrations. For spruce NO2 deposition velocity ranged between 0.07 and 0.42mms−1 (per leaf area) and NO2 compensation point  concentration ranged between 0.17 and 0.65 ppb. Under our field conditions NO2 deposition velocities would have been overestimated up to 80 %, if NO2 photolysis has not been considered. We also quantified the photolysis component for some previous NO2 flux measurements. Neglecting photo-chemical reactions may have changed reported NO2 compensation point concentration by 10%. However, the effect on NO2 deposition velocity was much more intense, ranged between 50 and several hundreds percent. Our findings may have consequences for the results from previous studies and ongoing discussion of NO2 compensation point concentrations.

Weitere Angaben

Publikationsform: Artikel in einer Zeitschrift
Begutachteter Beitrag: Nein
Zusätzliche Informationen: BAYCEER101315
Institutionen der Universität: Forschungseinrichtungen > Forschungszentren > Bayreuther Zentrum für Ökologie und Umweltforschung - BayCEER
Forschungseinrichtungen
Forschungseinrichtungen > Forschungszentren
Titel an der UBT entstanden: Ja
Themengebiete aus DDC: 500 Naturwissenschaften und Mathematik
Eingestellt am: 29 Jul 2015 05:53
Letzte Änderung: 29 Jul 2015 05:53
URI: https://eref.uni-bayreuth.de/id/eprint/17320