Welzl, Matthias ; Heberle, Florian ; Brüggemann, Dieter:
Experimental evaluation of nucleate pool boiling heat transfer correlations for R245fa and R1233zd(E) in ORC applications.
In: Renewable Energy. Bd. 147 (2020) Heft 3 . - S. 2855-2864.
ISSN 1879-0682
DOI: https://doi.org/10.1016/j.renene.2018.09.093

Angaben zu Projekten

Projektfinanzierung: Bayerisches Staatsministerium für Wissenschaft, Forschung und Kunst

Abstract

In binary geothermal power plants based on the Organic Rankine Cycle (ORC) typically shell-and-tube heat exchangers are used as evaporators. In the shell-side, nucleate boiling of the working fluid takes place on the external surfaces of tubes. For the replacement of fluids with high global warming potential (GWP) or selection of efficient working fluids, a comprehensive evaluation has to be performed. Therefore, the knowledge about the nucleate pool boiling heat transfer coefficient (HTC) in combination with the electrical power output is necessary. In this study, the focus is led on the experimental evaluation of nucleate pool boiling heat transfer correlations for R245fa and its possible replacement R1233zd(E) in ORC applications. The nucleate boiling HTC on a horizontal tube and the electrical power generation of a 1 kW scroll expander are simultaneously measured with an ORC test rig for both fluids. The thermal input is provided by an electrically heated preheater and evaporator. Nucleate boiling takes place on a plain copper tube with an outer diameter of 32 mm and a heated length of 822 mm. The surface temperature of the copper tube is determined by thermocouples within the tube in consideration of thermal conduction. The obtained measurement results, regarding heat transfer characteristics as well as power output, show that the working fluid R245fa performs better at equal saturation temperatures due to the higher density and saturation pressure, and the lower viscosity. The HTC for R245fa is up to 43.2% higher in comparison to R1233zd(E). The experimental HTC are compared to selected nucleate pool boiling HTC correlations. The evaluation reveals that correlations according to Cooper and Gorenflo et al. show the slightest mean absolute deviations between 4.75% and 15.65% for both working fluids.

Weitere Angaben

Publikationsform: Artikel in einer Zeitschrift
Begutachteter Beitrag: Ja
Keywords: Organic Rankine Cycle; Pool boiling; Low GWP; Geothermal; R245fa; R1233zd(E)
Institutionen der Universität: Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Technische Thermodynamik und Transportprozesse
Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Technische Thermodynamik und Transportprozesse > Lehrstuhl Technische Thermodynamik und Transportprozesse - Univ.-Prof. Dr.-Ing. Dieter Brüggemann
Profilfelder > Emerging Fields > Energieforschung und Energietechnologie
Forschungseinrichtungen > Forschungsstellen > ZET - Zentrum für Energietechnik
Fakultäten
Fakultäten > Fakultät für Ingenieurwissenschaften
Profilfelder
Profilfelder > Emerging Fields
Forschungseinrichtungen
Forschungseinrichtungen > Forschungsstellen
Titel an der UBT entstanden: Ja
Themengebiete aus DDC: 600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften
Eingestellt am: 15 Mär 2019 07:20
Letzte Änderung: 31 Jan 2020 08:25
URI: https://eref.uni-bayreuth.de/id/eprint/47276