Jaeger, Katharina M. ; Nissen, Michael ; Flaucher, Madeleine ; Graf, Luisa ; Joanidopoulos, Joana ; Anneken, Lars ; Huebner, Hanna ; Goossens, Chloë ; Titzmann, Adriana ; Pontones, Constanza ; Fasching, Peter A. ; Beckmann, Matthias W. ; Eskofier, Bjoern M. ; Leutheuser, Heike:
Systematic Comparison of ECG Delineation Algorithm Performance on Smartwatch Data.
In: IEEE Access. Bd. 12 (2024) . - S. 160794-160804.
ISSN 2169-3536
DOI: https://doi.org/10.1109/ACCESS.2024.3487013

Abstract

Cardiovascular diseases are the leading cause of global mortality, necessitating early detection and continuous monitoring for timely interventions. Smartwatches with electrocardiogram (ECG) recording capabilities enable real-time, at-home cardiac monitoring. Specific ECG characteristics can provide insights into cardiovascular diseases. The delineation of ECGs, which is the identification of fiducial points (such as onsets, offsets, and peaks), is a time-consuming task. Automated ECG delineation can enhance this process, but existing research comparing available algorithms is limited. Furthermore, to the best of our knowledge, none have addressed single-lead ECGs from smartwatches, which can be noisy and unfiltered. Thus, this study evaluates the best-performing open-source algorithm for single-lead and smartwatch ECG data. We used two public datasets (Lobachevsky University Database, QT Database) and two smartwatch datasets (SmartHeartWatch Dataset, SMART Start Dataset) including two devices (Apple Watch, Withings ScanWatch). Algorithms from three toolkits (NeuroKit, ECGKit, ECGdeli) were assessed based on the time deviation between algorithm outputs and reference annotations, sensitivity, true positives, and false negatives. Results were further evaluated against the Common Standards for Quantitative Electrocardiography (CSE) recommendations. ECGdeli outperformed the other algorithms. For QRS on- and offset, ECGkit shows comparable sensitivity, but otherwise lower scores. NeuroKit consistently shows lower sensitivity across all four data sets, however, the temporal deviation between detected point and reference was higher. Overall, sensitivity scores were higher for Apple Watch data compared to Withings ScanWatch data. This study demonstrates that segmentation algorithms are applicable to single-lead smartwatch ECG data, with ECGdeli being the most stable overall, and NeuroKit recommended for scenarios prioritizing the temporal accuracy of detected points.

Weitere Angaben

Publikationsform: Artikel in einer Zeitschrift
Begutachteter Beitrag: Ja
Keywords: Electrocardiography; Wearable Health Monitoring Systems; Monitoring; Recording; Cardiovascular diseases; Databases; Feature extraction; Annotations; Sensitivity; Pregnancy; Cardiovascular diseases; mobile health; ECG segmentation; wearable devices
Institutionen der Universität: Fakultäten > Fakultät für Mathematik, Physik und Informatik
Fakultäten > Fakultät für Mathematik, Physik und Informatik > Institut für Informatik
Fakultäten > Fakultät für Mathematik, Physik und Informatik > Institut für Informatik > Lehrstuhl Ambient Assisted Living und Medizinische Assistenzsysteme
Fakultäten > Fakultät für Mathematik, Physik und Informatik > Institut für Informatik > Lehrstuhl Ambient Assisted Living und Medizinische Assistenzsysteme > Lehrstuhl Ambient Assisted Living und Medizinische Assistenzsysteme - Univ.-Prof. Dr. Heike Leutheuser
Titel an der UBT entstanden: Nein
Themengebiete aus DDC: 000 Informatik,Informationswissenschaft, allgemeine Werke
600 Technik, Medizin, angewandte Wissenschaften
Eingestellt am: 24 Feb 2026 07:58
Letzte Änderung: 24 Feb 2026 07:58
URI: https://eref.uni-bayreuth.de/id/eprint/96337