Titelangaben
Brandenburg, Annica ; Wappler, Eberhard ; Moos, Ralf ; Kita, Jaroslaw:
Development and optimization of a novel miniaturized ceramic differential scanning calorimeter.
2014
Veranstaltung: Thermal Analysis and Calorimetry in Industry and Research - 40 Years of GEFTA
, Sept. 16 - 19, 2014
, Berlin.
(Veranstaltungsbeitrag: Kongress/Konferenz/Symposium/Tagung
,
Vortrag
)
Weitere URLs
Angaben zu Projekten
Projekttitel: |
Offizieller Projekttitel Projekt-ID Ohne Angabe KF2116719WM2 |
---|---|
Projektfinanzierung: |
Bundesministerium für Wirtschaft und Technologie |
Abstract
Differential scanning calorimetry (DSC) is widely-used to analyze thermodynamic material properties. However, materials that form aggressive or corrosive reaction products cannot be easily analyzed with conventional DSC devices, since they contaminate or damage these highly complex and cost-intensive apparatuses. Moreover, classical DSC devices are designed as stationary table top units and therefore are not suitable for mobile usage. To allow for mobile DSC applications and for the detection of aggressive materials, the objective of our work is to develop a low-cost miniaturized ceramic differential scanning calorimeter device that consists of only one single chip that includes all functional elements, i.e. crucible, sample and reference temperature sensors, heater, and reference. In this article, the development process of this miniaturized DSC chip is presented: Utilizing finite element method (FEM), the DSC chip was stepwise developed and optimized, leading to a well-functioning device of a size of only 11 mm x 39 mm x 1.2 mm. In the sensor head, crucible, sample and reference temperature sensors, heater, and reference are vertically integrated. Due to its small size, the power consumption is below 2.5 W, enabling the user to run the sensor system via USB connection directly from a laptop. The DSC chip is fully manufactured in Low Temperature Co-firing Ceramics (LTCC) Technology. The use of ceramics as substrate material ensures high temperature stability allowing for DSC analysis up to 650 °C with high heating rates up to 300 K/min. A calorimetric sensitivity of 0.24 W/K was found. Furthermore, resolution tests with Dotriacontane as test substance revealed temperature resolution which is comparable to conventional devices.
Weitere Angaben
Publikationsform: | Veranstaltungsbeitrag (Vortrag) |
---|---|
Begutachteter Beitrag: | Ja |
Institutionen der Universität: | Fakultäten > Fakultät für Ingenieurwissenschaften Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Funktionsmaterialien > Lehrstuhl Funktionsmaterialien - Univ.-Prof. Dr.-Ing. Ralf Moos Fakultäten Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Funktionsmaterialien Profilfelder > Advanced Fields > Neue Materialien Forschungseinrichtungen > Forschungszentren > Bayreuther Materialzentrum - BayMAT Profilfelder Profilfelder > Advanced Fields Forschungseinrichtungen Forschungseinrichtungen > Forschungszentren |
Titel an der UBT entstanden: | Ja |
Themengebiete aus DDC: | 600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften |
Eingestellt am: | 11 Mai 2015 10:37 |
Letzte Änderung: | 13 Nov 2015 10:15 |
URI: | https://eref.uni-bayreuth.de/id/eprint/13163 |