Radio-Frequency-Based NH₃-Selective Catalytic Reduction Catalyst Control : Studies on Temperature Dependency and Humidity Influences

Titelangaben

Dietrich, Markus ; Hagen, Gunter ; Reitmeier, Willibald ; Burger, Katharina ; Hien, Markus ; Grass, Philippe ; Kubinski, David J. ; Visser, Jacobus H. ; Moos, Ralf:
Radio-Frequency-Based NH₃-Selective Catalytic Reduction Catalyst Control : Studies on Temperature Dependency and Humidity Influences.
In: Sensors. Bd. 17 (2017) Heft 7 . - Article number: 1615.
ISSN 1424-8220
DOI: https://doi.org/10.3390/s17071615

Angaben zu Projekten

Projekttitel:
Offizieller Projekttitel
Projekt-ID
Open Access Publizieren
Ohne Angabe

Abstract

The upcoming more stringent automotive emission legislations and current developments have promoted new technologies for more precise and reliable catalyst control. For this purpose, radio-frequency-based (RF) catalyst state determination offers the only approach for directly measuring the NH3 loading on selective catalytic reduction (SCR) catalysts and the state of other catalysts and filter systems. Recently, the ability of this technique to directly control the urea dosing on a current NH3 storing zeolite catalyst has been demonstrated on an engine dynamometer for the first time and this paper continues that work. Therefore, a well-known serial-type and zeolite-based SCR catalyst (Cu-SSZ-13) was investigated under deliberately chosen high space velocities. At first, the full functionality of the RF system with Cu-SSZ-13 as sample was tested successfully. By direct RF-based NH3 storage control, the influence of the storage degree on the catalyst performance, i.e., on NOx conversion and NH3 slip, was investigated in a temperature range between 250 and 400 °C. For each operation point, an ideal and a critical NH3 storage degree was found and analyzed in the whole temperature range. Based on the data of all experimental runs, temperature dependent calibration functions were developed as a basis for upcoming tests under transient conditions. Additionally, the influence of exhaust humidity was observed with special focus on cold start water and its effects to the RF signals.

Weitere Angaben

Publikationsform: Artikel in einer Zeitschrift
Begutachteter Beitrag: Ja
Keywords: radio-frequency (RF); NH3 SCR; NH3 storage; direct control; microwave cavity perturbation; exhaust gas sensor; cold start
Institutionen der Universität: Fakultäten > Fakultät für Ingenieurwissenschaften
Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Funktionsmaterialien > Lehrstuhl Funktionsmaterialien - Univ.-Prof. Dr.-Ing. Ralf Moos
Profilfelder > Advanced Fields > Neue Materialien
Forschungseinrichtungen > Forschungszentren > Bayreuther Materialzentrum - BayMAT
Forschungseinrichtungen > Forschungsstellen > BERC - Bayreuth Engine Research Center
Fakultäten
Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Funktionsmaterialien
Profilfelder
Profilfelder > Advanced Fields
Forschungseinrichtungen
Forschungseinrichtungen > Forschungszentren
Forschungseinrichtungen > Forschungsstellen
Titel an der UBT entstanden: Ja
Themengebiete aus DDC: 600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften
Eingestellt am: 17 Jul 2017 09:01
Letzte Änderung: 26 Apr 2018 11:00
URI: https://eref.uni-bayreuth.de/id/eprint/38460