Donker, Nils ; Ruchets, Anastasiya ; Schönauer-Kamin, Daniela ; Zosel, Jens ; Guth, Ulrich ; Moos, Ralf:
Pulse polarization measurements on the system Pt|YSZ by varying the polarization voltage.
2019
Veranstaltung: 7th Regional Symposium on Electrochemistry of South-East Europe
, 27.-30. Mai 2019
, Split, Croatia.
(Veranstaltungsbeitrag: Kongress/Konferenz/Symposium/Tagung
,
Vortrag
)
Abstract
Most sensors for nitrogen oxides (NOx; NO and NO2) are based on potentiometric (equilibrium and non-equilibrium), amperometric, or impedancemetric principles to detect the concentration of NOx in the atmosphere. All these methods have in common that they reach a steady state value at a constant atmosphere after certain time. In contrast, the pulsed polarization method is a dynamic method and it utilizes the well-known Pt|YSZ-system. Platinum electrodes are screen-printed on both sides of a YSZ substrate for this purpose. Both sensor electrodes are exposed to the same gas atmosphere at the same temperature. Therefore, a potentiometric measurement would result in the voltage difference 0 V. To receive a signal, the sensor is brought out of its equilibrium state. In order to do this, the sensor is polarized with the polarization voltage Upol for a duration t_pol. The sensor then automatically discharges after the voltage source has been removed. It could be shown that the self-discharge accelerates strongly with increasing NOx concentration. After the discharge time tdischarge, the sensor is polarized again for the duration tpol, but with the opposite sign -Upol. Such a cycle with alternating polarization and intermediate discharge is schematically shown in Fig. 1a. A sensor signal can be generated on the basis of the voltage values at a defined point in time in the cycle. Examples for such points in time are schematically marked as U_signal1 and U_signal2. In the case of a perfectly symmetrical sensor design, the magnitude of these voltages is the same in terms of measurement accuracy. In this study, the operation of the pulse polarization with different polarization voltages shall be shown. It can be expected that the voltage and the resulting reactions will have a significant influence on the sensor signal. Some results measured at various polarization voltages (100, 500 and 1000 mV) are shown in Fig. 1b. Here, the voltages 3 seconds after the beginning of each cycle are displayed.
Weitere Angaben
Publikationsform: | Veranstaltungsbeitrag (Vortrag) |
---|---|
Begutachteter Beitrag: | Ja |
Institutionen der Universität: | Fakultäten > Fakultät für Ingenieurwissenschaften Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Funktionsmaterialien > Lehrstuhl Funktionsmaterialien - Univ.-Prof. Dr.-Ing. Ralf Moos Profilfelder > Advanced Fields > Neue Materialien Forschungseinrichtungen > Forschungszentren > Bayreuther Materialzentrum - BayMAT Fakultäten Fakultäten > Fakultät für Ingenieurwissenschaften > Lehrstuhl Funktionsmaterialien Profilfelder Profilfelder > Advanced Fields Forschungseinrichtungen Forschungseinrichtungen > Forschungszentren |
Titel an der UBT entstanden: | Ja |
Themengebiete aus DDC: | 600 Technik, Medizin, angewandte Wissenschaften > 620 Ingenieurwissenschaften |
Eingestellt am: | 12 Jun 2019 06:51 |
Letzte Änderung: | 12 Jun 2019 06:51 |
URI: | https://eref.uni-bayreuth.de/id/eprint/49459 |