Title data
Schönauer-Kamin, Daniela ; Nauwerck, Andreas ; Gysin, Till ; Moos, Ralf:
Detection of Water Condensation on Exhaust Gas Sensors.
In:
Proceedings SENSOR 2009. -
Wunstorf
: AMA Verband für Sensorik und Messtechnik e.V.
,
2009
. - pp. 403-406
ISBN 978-3-9810993-5-5
DOI: https://doi.org/10.5162/sensor09/v2/p5.5
Related URLs
Abstract in another language
An interdigital H2O sensing structure applied on a ceramic element provides the possibility to determine the water condensation process in the exhaust system of an internal combustion engine during cold-start. In lab tests, a clear correlation between capacity change and water droplet size was found. In engine cold start tests it was proven that the start and the end points of the water condensation processes can be detected.
Further data
Item Type: | Article in a book |
---|---|
Refereed: | Yes |
Institutions of the University: | Faculties > Faculty of Engineering Science Faculties > Faculty of Engineering Science > Chair Functional Materials > Chair Functional Materials - Univ.-Prof. Dr.-Ing. Ralf Moos Faculties Faculties > Faculty of Engineering Science > Chair Functional Materials Profile Fields > Advanced Fields > Advanced Materials Research Institutions > Research Centres > Bayreuth Center for Material Science and Engineering - BayMAT Profile Fields Profile Fields > Advanced Fields Research Institutions Research Institutions > Research Centres |