Development and optimization of a novel miniaturized ceramic differential scanning calorimeter

Title data

Brandenburg, Annica ; Wappler, Eberhard ; Moos, Ralf ; Kita, Jaroslaw:
Development and optimization of a novel miniaturized ceramic differential scanning calorimeter.
2014
Event: Thermal Analysis and Calorimetry in Industry and Research - 40 Years of GEFTA , Sept. 16 - 19, 2014 , Berlin.
(Conference item: Conference , Speech )

Related URLs

Project information

Project title:
Project's official title
Project's id
No information
KF2116719WM2

Project financing: Bundesministerium für Wirtschaft und Technologie

Abstract in another language

Differential scanning calorimetry (DSC) is widely-used to analyze thermodynamic material properties. However, materials that form aggressive or corrosive reaction products cannot be easily analyzed with conventional DSC devices, since they contaminate or damage these highly complex and cost-intensive apparatuses. Moreover, classical DSC devices are designed as stationary table top units and therefore are not suitable for mobile usage. To allow for mobile DSC applications and for the detection of aggressive materials, the objective of our work is to develop a low-cost miniaturized ceramic differential scanning calorimeter device that consists of only one single chip that includes all functional elements, i.e. crucible, sample and reference temperature sensors, heater, and reference. In this article, the development process of this miniaturized DSC chip is presented: Utilizing finite element method (FEM), the DSC chip was stepwise developed and optimized, leading to a well-functioning device of a size of only 11 mm x 39 mm x 1.2 mm. In the sensor head, crucible, sample and reference temperature sensors, heater, and reference are vertically integrated. Due to its small size, the power consumption is below 2.5 W, enabling the user to run the sensor system via USB connection directly from a laptop. The DSC chip is fully manufactured in Low Temperature Co-firing Ceramics (LTCC) Technology. The use of ceramics as substrate material ensures high temperature stability allowing for DSC analysis up to 650 °C with high heating rates up to 300 K/min. A calorimetric sensitivity of 0.24 W/K was found. Furthermore, resolution tests with Dotriacontane as test substance revealed temperature resolution which is comparable to conventional devices.

Further data

Item Type: Conference item (Speech)
Refereed: Yes
Institutions of the University: Faculties > Faculty of Engineering Science
Faculties > Faculty of Engineering Science > Chair Functional Materials > Chair Functional Materials - Univ.-Prof. Dr.-Ing. Ralf Moos
Faculties
Faculties > Faculty of Engineering Science > Chair Functional Materials
Profile Fields > Advanced Fields > Advanced Materials
Research Institutions > Research Centres > Bayreuth Center for Material Science and Engineering - BayMAT
Profile Fields
Profile Fields > Advanced Fields
Research Institutions
Research Institutions > Research Centres
Result of work at the UBT: Yes
DDC Subjects: 600 Technology, medicine, applied sciences > 620 Engineering
Date Deposited: 11 May 2015 10:37
Last Modified: 13 Nov 2015 10:15
URI: https://eref.uni-bayreuth.de/id/eprint/13163